- Material
- Dimensional
- Test & Inspection
Housing Material Options
- PIPE : 1. SEAMLESS CS ASTM A106 GR.B, SCH.-40, 2. ASTM A312 TP 304, SCH.-40
- FLANGE : 1. IS 2062 / ASTM A105, 2. ASTM A351 GR. CF8
Lining Material Options
- PFA – ASTM D 3307
- FEP – ASTM D 2116
- ETFE – ASTM D 3159
- PVDF – ASTM D 3322
- PP – ASTM D 4101
- HDPE
Dimensional Data
ANSI #150 Flanged | ||||||
SIZE |
ØA (mm) | ØC(mm) |
H(mm) |
S (MIN.) (mm) | Approx Weight (Kg) | |
FOR 1 Mtr. | Additional Kg./Mtr. | |||||
DN25-1” | 20.5 | 51 | 2.3 | 3.0 | 4.69 | 2.95 |
DN40-1 1/2” | 33.5 | 73 | 3.0 | 3.25 | 7.92 | 4.97 |
DN50-2” | 45.5 | 92 | 3.0 | 3.25 | 11.04 | 6.63 |
DN80-3” | 70.9 | 127 | 3.5 | 4.0 | 21.96 | 13.74 |
DN100-4” | 94 | 157 | 3.5 | 4.5-5.0 | 30.52 | 19.4 |
DN150-6” | 144.1 | 216 | 4.5 | 6.0-6.5 | On Request | On Request |
DN200-8” | 190.7 | 270 | 5.0 | Consult Factory | On Request | On Request |
Lined Pipe Vacuum Resistance (in inch of Mercury) | ||||||
Material | Temp. | 25 NB | 40 NB | 50 NB | 80 NB 100 NB | |
21°c | Full | Full | Full | Full | Full | |
PTFE | 100°c | Full | Full | Full | Full | Full |
175°c | Full | Full | Full | Full | Full | |
21°c | Full | Full | Full | Full | Full | |
PVDF | 85°c | Full | Full | Full | Full | Full |
135°c | Full | Full | Full | Full | Full | |
PP | 21°c | Full | Full | Full | Full | Full |
95°c | Full | Full | Full | Full | Full | |
HDPE | 21°c | Full | Full | Full | Full | Full |
65°c | Full | Full | Full | Full | Full |
- Consult “Hi-Tech Applicator” for vacuum services. Special Heavy Duty PTFE Liners vailable for full vacuum. Details can be provided on request. Other Flange Drillings like, DIN 2632 / 2633 , BS 10 Table D, E or F are also available on request.
- Max. Length available : 3 Mtr.
- Tolerance : ±3.5mm (0 to 1 Mtr.) and ±5.0mm (1 to 3 Mtr.)
- Clear ID for HDPE/PP Lined Pipes (DN/ID): 25/18 , 40/32 , 50/42 , 65/57 , 80/67
Test & Inspection Data
- Resins are confirming to the requirements of ASTM F1545-97 (2003)
- Hydraulic Test : 29 Kg/Cm2 After Lining
- Spark Test : 15 KV D.C After Lining
Technical Information subject to change without notice.