lined_pipe_non_jacketed
lined_pipe_non_jacketed_line_diagram
  • Material
  • Dimensional
  • Test & Inspection

Housing Material Options

  • PIPE : 1. SEAMLESS CS ASTM A106 GR.B, SCH.-40, 2. ASTM A312 TP 304, SCH.-40
  • FLANGE : 1. IS 2062 / ASTM A105, 2. ASTM A351 GR. CF8

Lining Material Options

  • PFA – ASTM D 3307
  • FEP – ASTM D 2116
  • ETFE – ASTM D 3159
  • PVDF – ASTM D 3322
  • PP – ASTM D 4101
  • HDPE

Dimensional Data

ANSI #150 Flanged

SIZE

ØA (mm) ØC(mm)

H(mm)

S (MIN.) (mm) Approx Weight (Kg)
FOR 1 Mtr. Additional Kg./Mtr.
DN25-1” 20.5 51 2.3 3.0 4.69 2.95
DN40-1 1/2” 33.5 73 3.0 3.25 7.92 4.97
DN50-2” 45.5 92 3.0 3.25 11.04 6.63
DN80-3” 70.9 127 3.5 4.0 21.96 13.74
DN100-4” 94 157 3.5 4.5-5.0 30.52 19.4
DN150-6” 144.1 216 4.5 6.0-6.5 On Request On Request
DN200-8” 190.7 270 5.0 Consult Factory On Request On Request
Lined Pipe Vacuum Resistance (in inch of Mercury)
Material Temp. 25 NB 40 NB 50 NB 80 NB 100 NB
21°c Full Full Full Full Full
PTFE 100°c Full Full Full Full Full
175°c Full Full Full Full Full
21°c Full Full Full Full Full
PVDF 85°c Full Full Full Full Full
135°c Full Full Full Full Full
PP 21°c Full Full Full Full Full
95°c Full Full Full Full Full
HDPE 21°c Full Full Full Full Full
65°c Full Full Full Full Full
  • Consult “Hi-Tech Applicator” for vacuum services. Special Heavy Duty PTFE Liners vailable for full vacuum. Details can be provided on request. Other Flange Drillings like, DIN 2632 / 2633 , BS 10 Table D, E or F are also available on request.
  • Max. Length available : 3 Mtr.
  • Tolerance : ±3.5mm (0 to 1 Mtr.) and ±5.0mm (1 to 3 Mtr.)
  • Clear ID for HDPE/PP Lined Pipes (DN/ID): 25/18 , 40/32 , 50/42 , 65/57 , 80/67

Test & Inspection Data

  • Resins are confirming to the requirements of ASTM F1545-97 (2003)
  • Hydraulic Test : 29 Kg/Cm2 After Lining
  • Spark Test : 15 KV D.C After Lining

Technical Information subject to change without notice.