Special Installation Instruction
- When Installed Vertically (or upto 60° angle) check valve close automatically because of centre guided ball.
- When Installed Horizontally (90° to 60°), the valve close automatically if the back flow related to water is 1.5 – 2.5 m/sec.
- Full Bore when valve is opened. i.e. Low Pressure Drop condition.
Standard Scope Of Supply
NO. | Description | MOC |
---|---|---|
1. | Body With Lining | Ductile Iron GGG40.3 /ASTM Gr.WCB (FEP Lined) † |
2. | Cover Plate | Ductile Iron GGG 40.3 /ASTM A216 Gr.WCB |
3. | Glass | Toughen Glass |
4. | Cushion | PTFE |
5. | Bolts | M.S (Zinc Plated) |
6. | Nuts | M.S (Zinc Plated) |
† Standard Scope of Supply
Salient Features
- Drip Tube Indication
- Inert to a wide range of Corrosive Chemicals
- Eliminates need of using expensive, exotic alloys.
Technical Specifications
- Flange : As per ANSI B16.5 / B16.42
- Face to Face : DIN 3202
- Lining Thickness : 3 to 5 mm
- Material
- Dimensional
- Test & Inspection
- Optional Design
Body Material Options
- Ductile Iron GGG40.3 / ASTM A395
- Cast Steel ASTM A216 Gr.WCB
- ASTM A351 Gr. CF8 / AISI S.S.304
- ASTM A351 Gr. CF8M / AISI S.S.316
Lining Material Options
- PFA – ASTM D 3307
- FEP – ASTM D 2116
- PVDF – ASTM D 3322
- PP – ASTM D 4101
Dimensional Data
ANSI #150 FLANGED RF | ||
SIZE | A*(mm) | ØG (mm) |
DN25-1” | 160 | 45 |
DN40-1 1/2” | 200 | 60 |
DN50-2” | 230 | 70 |
DN80-3” | 310 | 98 |
DN100-4” | 350 | 125 |
DN150-6” | 480 | 175 |
DN200-8” | 600 | 216 |
Test & Inspection Data
- Hydraulic Test : Body(Shell) – 15 Kg/Cm
- Spark Test : 15 K.V. D.C
Optional Design & Components
- FULL VIEW (GLASS TUBE) DESIGN
Technical Information subject to change without notice.