inline_sampling_valve_non_j
inline_sampling_valve_line_diagram

Standard Scope Of Supply

NO. Description MOC
1. Body With Lining Ductile Iron GGG 40.3 / C.I. (FEP Lined) †
2. End Cover Ductile Iron GGG 40.3 / C.I. (FEP Lined) †
3. Stud / Nut S.S.
4. Filter Element PTFE / PFA
5. Drain Plug PTFE / PFA

Salient Features

  • True & Representative Sample Every Time.
  • Flange : As per ANSI B16.5 / B16.42
  • Always Under Isolation While Sampling – Higher Safety.
  • 100% Maintenance Free Design
  • Safe – True – Reliable Sample Without Any Process Interruption.

Technical Specifications

  • Design Standard : Manufacturer’s Standard
  • Flange : As per ANSI B16.5 / B16.42
  • Drilling : ASA #150 /DIN 2632/33 / BS 10 TABLE D, E, F
  • Lining Thickness : 3 to 5 mm
  • Testing Standard : BS EN 12266-1&2 (2003)
  • Material
  • Dimensional
  • Test & Inspection
  • Optional Design

Body Material Options

  • ASTM A106 Gr. B, Sch-40 Pipe + A105 Flange
  • ASTM A351 Gr. CF8 / S.S.304
  • ASTM A351 Gr. CF8M / S.S.316

Lining Material Options

  • PFA – ASTM D 3307
  • FEP – ASTM D 2116
  • PVDF – ASTM D 3322

Dimensional Data

ANSI #150 FLANGED RF
SIZE L$ (mm) Sample Capacity
DN25-1” 250 50 ML
DN40-1 1/2” 250 50 ML
DN50-2” 250 50 ML
DN80-3” 250 75 ML
DN100-4” 250 75 ML
  • * As per Manufacturer’s Standard.
  • # Testing in accordance with BS EN 12266-1(2003) Table A.3

>

Test & Inspection Data

  • Hydraulic Test # : Body (Shell) – 15 Kg/Cm2, Seat – 10 Kg/Cm2
  • Pneumatic Test # : Seat – 6 Kg/Cm2
  • Spark Test : 15 K.V. D.C

Optional Design & Components

  • Sampling Cabinet
  • Anti-Static Teflon® Pfa Lining
  • Jacketed Sampling Valve
  • Un-Lined Sampling Valve

Technical Information subject to change without notice.